Reference Guide
Table Of Contents
- Dell Command | Monitor Version 10.5 Reference Guide
- Contents
- Introduction for Dell Command | Monitor 10.5
- Dell Command | Monitor 10.5 Namespaces
- Profiles for Dell Command | Monitor 10.5
- Classes for Dell Command | Monitor 10.5
- Dell Command | Monitor 10.5 classes and properties
- Classes supported for systems running Linux
- Classes supported for systems running Windows
- DCIM_AlertIndication
- DCIM_ApplicationProxySetting
- DCIM_BaseMetricDefinition
- DCIM_Card
- DCIM_Chassis
- DCIM_Chip
- DCIM_DesktopMonitor
- DCIM_DHCPProtocolEndpoint
- DCIM_EthernetPort
- DCIM_FlatPanel
- DCIM_IPProtocolEndpoint
- DCIM_ImprovementProgramConsent
- DCIM_ControllerView
- DCIM_PhysicalDiskView
- DCIM_VirtualDiskView
- DCIM_PhysicalMemory
- DCIM_PhysicalPackage
- DCIM_ParallelPort
- DCIM_RemoteServiceAccessPoint
- DCIM_Slot
- DCIM_SerialPort
- DCIM_USBPort
- DCIM_Memory
- DCIM_PCIDevice
- DCIM_DisplayController
- DCIM_Fan
- DCIM_IndicatorLED
- DCIM_PowerSupply
- DCIM_Battery
- DCIM_Processor
- DCIM_NumericSensor
- DCIM_Sensor
- DCIM_DeviceBay
- DCIM_VideoHead
- DCIM_Button
- DCIM_LCDPanel
- DCIM_NetworkPortConfigurationService
- DCIM_TimeService
- DCIM_AccountManagementService
- DCIM_RoleBasedAuthorizationService
- DCIM_PowerManagementService
- DCIM_BootService
- DCIM_IPConfigurationService
- DCIM_PowerUtilizationManagementService
- DCIM_BIOSService
- DCIM_SoftwareInstallationService
- DCIM_ComputerSystem
- DCIM_RecordLog
- DCIM_OperatingSystem
- DCIM_SoftwareIdentity
- DCIM_BIOSElement
- DCIM_ConcreteJob
- DCIM_BootSourceSetting
- DCIM_BootConfigSetting
- DCIM_IPAssignmentSettingData
- DCIM_PowerAllocationSettingData
- DCIM_AssetAcquisition
- DCIM_AssetExtendedWarrantyInformation
- DCIM_AssetOwnerInformation
- DCIM_AssetSupportInformation
- DCIM_AssetWarrantyInformation
- DCIM_AssetSystemInformation
- DCIM_ThermalInformation
- DCIM_AMTSettings
- DCIM_ASFSettings
- DCIM_VProSettings
- DCIM_AlertIndicationSettingData
- DCIM_HDDAlertIndicationSettingData
- DCIM_BaseMetricValue
- DCIM_LogEntry
- DCIM_IndicatorLEDCapabilities
- DCIM_ProcessorCapabilities
- DCIM_AccountManagementCapabilities
- DCIM_BootServiceCapabilities
- DCIM_PlatformWatchdogServiceCapabilities
- DCIM_DHCPCapabilities
- DCIM_PowerUtilizationManagementCapabilities
- DCIM_EnabledLogicalElementCapabilities
- DCIM_ButtonCapabilities
- DCIM_LCDPanelCapabilities
- DCIM_PowerManagement
- DCIM_PhysicalAssetCapabilities
- DCIM_RoleBasedManagementCapabilities
- DCIM_AllocationCapabilities
- DCIM_BIOSServiceCapabilities
- DCIM_SoftwareInstallationServiceCapabilities
- DCIM_ConcreteCollection
- DCIM_RedundancySet
- DCIM_Role
- DCIM_IndicationSettingCollection
- DCIM_ConfigurationCapacity
- DCIM_Location
- DCIM_BIOSEnumeration
- DCIM_BIOSPassword
- DCIM_BIOSString
- DCIM_MemoryError
- DCIM_IdentityContext
- DCIM_OrderedComponent
- DCIM_Container
- DCIM_ConcreteComponent
- DCIM_SystemDevice
- DCIM_AccountOnSystem
- DCIM_InstalledOS
- DCIM_SystemBIOS
- DCIM_SystemComponent
- DCIM_SettingsDefineCapabilities
- DCIM_DeviceSAPImplementation
- DCIM_HostedAccessPoint
- DCIM_HostedCollection
- DCIM_HostedService
- DCIM_VideoHeadOnController
- DCIM_SAPSAPDependency
- DCIM_ReferencedProfile
- DCIM_MetricDefForME
- DCIM_MetricForME
- DCIM_MetricInstance
- DCIM_ElementInConnector
- DCIM_Docked
- DCIM_ConcreteDependency
- DCIM_Realizes
- DCIM_ComputerSystemPackage
- DCIM_RunningOS
- DCIM_UseOfLog
- DCIM_AssociatedIndicatorLED
- DCIM_AssociatedCacheMemory
- DCIM_AssociatedSensor
- DCIM_RemoteAccessAvailableToElement
- DCIM_ServiceServiceDependency
- DCIM_DeviceConnection
- DCIM_ElementSoftwareIdentity
- DCIM_ElementCapabilities
- DCIM_ElementSettingData
- DCIM_OrderedMemberOfCollection
- DCIM_MemberOfCollection
- DCIM_OwningCollectionElement
- DCIM_ElementConformsToProfile
- DCIM_RoleLimitedToTarget
- DCIM_ElementCapacity
- DCIM_ServiceAffectsElement
- DCIM_AssociatedPowerManagementService
- DCIM_ServiceAvailableToElement
- DCIM_LogManagesRecord
- DCIM_InstalledSoftwareIdentity
- DCIM_ConcreteIdentity
- DCIM_SMARTAttributeInfo
- DCIM_SettingsDefineState
- DCIM_ElementLocation
- DCIM_CredentialContext
- DCIM_OwningJobElement
- BIOS settings supported in Dell Command | Monitor 10.5
- Alerts in Dell Command | Monitor 10.5
- Sample scripts for Dell Command | Monitor 10.5
Table 151. Events Polled by Dell Command | Monitor (continued)
Dell Command | Monitor Event
(Windows event log Number)
Description
FanProbe (1103) A cooling device has exceeded a minor threshold.
AlertCoolingDeviceFailure (1104) Cooling device sensor has detected a failure value.
AlertCoolingDeviceNonRecoverable
(1105)
Cooling device sensor has detected a nonrecoverable value.
AlertVoltageProbeWarning (1153) Voltage probe has detected a warning value.
AlertVoltageProbeFailure (1154) Voltage probe has detected a failure value.
AlertVoltageProbeNonRecoverable
(1155)
Voltage probe has detected a nonrecoverable value.
CurrentProbe (1203) An electrical current probe has exceeded a minor threshold.
One of the hard-disk drives is running out of free space.
AlertAmperageProbeFailure (1204) Amperage probe has detected a failure value.
AlertAmperageProbeNonRecoverabl
e (1205)
Amperage probe has detected a nonrecoverable value.
ChassisIntrusionNormal (1252) Chassis intrusion has returned to normal.
ChassisIntrusion (1254) System chassis intrusion alert.
EccMemory (1403) A memory checksum failure has occurred.
NOTE: This event is not supported on the system running RHEL.
RAIDControllerFailure (1801) A RAID controller has failed.
RAIDControllerOffline (1802) A RAID controller is offline.
RAIDControllerPowerOff (1803) A RAID controller is turned off.
AlertRaidControllerDegraded (1804) A RAID controller has degraded.
PhysicalDiskDegraded (1811) A physical hard-disk drive is degraded.
AlertPhysicalDiskRebuilding (1812) A physical hard-disk drive is rebuilding.
PhysicalDiskFailed (1813) A physical hard-disk drive has failed.
PhysicalDiskOffline (1814) A physical hard-disk drive is offline.
VitualDiskDegraded (1821) A virtual hard-disk drive is degraded.
VirtualDiskRebuilding (1822) A virtual hard-disk drive is rebuilding.
VirtualDiskFailed (1823) A virtual hard-disk drive has failed.
VirtualDiskOffline (1824) A virtual hard-disk drive is offline.
NumberOfDisksIncreased (2030) A hard-disk drive has been added.
NumberOfDisksDecreased (2031) A hard-disk drive has been removed.
MemorySizeIncreased (2032) The memory size has been increased.
MemorySizeDecreased (2033) The memory size has been decreased.
DiskCapacity (2034) In the current version, two user-defined thresholds are used. An event is generated
only when the conditions of both thresholds are met. The first threshold, expressed
as an absolute value in megabytes, specifies the size of the hard-disk drive to
be monitored. Hard-disk drives with a capacity smaller than the specified size are
ignored. The second threshold is expressed as a percentage of the hard-disk drive
size. An event is generated when the available free space on one of the monitored
hard-disk drives falls below this percentage.
Alerts in Dell Command | Monitor 10.5 313