Issue: After the setup password has been set in DINO-XPS-Win7 or any other platform, then those platforms do not allow you to
set the system password.
Issue: Windows failed to initiate DSM Data Manager service on a local system.
Resolution: Visual C++ Redistributable for Visual Studio 2015 must be installed.
On systems running Linux
Issue: While enumerating the supported BIOS features, the Report Logo Type may also be listed.
PossibleValueDescription may be blank, where (0) stands for Dell Logo and (1) stands for Custom Logo. IsReadOnly
value that is listed is False, whereas it must be True.
Issue: ‘Door’ open indication is generated although door is not opened.
Description: Occasionally ‘Door Open’ indication gets generated due to multiple operations running simultaneously. For example,
the BIOS settings are enumerated and configured continuously in a stress run.
Resolution: Chassis door open indication is repetitive and unless multiple alerts occur, this should not be serviced.
NOTE:
This behavior is rarely noticed. This issue is addressed in upcoming release.
Issue: Setting up BIOS configuration may occasionally fail.
Description: Failure messages are displayed while a user tries to apply BIOS configurations.
Resolution: Apply BIOS configuration settings again, and it is successful.
Issue: BIOS setting enumeration value appears as 1.
Description: Installing HAPI library from other source may not load the HAPI driver.
Resolution: Install HAPI package from Dell Command | Monitor tar package. If the package is installed, then load the driver
module by running the following command:
insmod <filename>
Issue: Element Name in DCIM_Card class returns blank or displays value (2) Unknown while enumeration.
Issue: Physical Disk View always displays value 2 (Unknown) for AF (Advance Format) Status for Physical Disks that are
managed by LSI controllers.
Issue: Dell Command | Monitor 9.2 for Linux, syslog entries on alerts are written only when CIM events are subscribed.
Issue: If Dell Command | Configure 4.2 and Dell Command | Monitor 10.0 (or any prior versions) are installed in the system, then
the Dell Command | Monitor 10.0 (or any prior versions) may not work.
Resolution:Upgrade Dell Command | Monitor to the latest version.
Issue: For the following BIOS Settings, setBIOSAttributes method displays incorrect value 0 (Success), while using the
unsupported possible values:
1. Keyboard Backlight Color Enable
2. Keyboard Backlight Custom Color 1
3. Keyboard Backlight Custom Color 2
Issue: The performance of Dell Command | Monitor 10.3 in Linux operating system regarding DCIM_BIOSEnumeration class is
slower on the systems that are running on kernel versions 4.15 or later.
18