Release Notes

Issue: For LSI controllers, status or event may not be generated when the Battery
Backup Unit (BBU) is degraded.
Resolution: The BBU degraded status can be viewed in the application log for event (Id
#161 of category type: Warning) generated by source MR_MONITOR.
Issue: After upgrading from Windows OS, enumerating WMI classes or walk of the
SNMP OID may not display appropriate results.
Resolution: Reinstall Dell Command | Monitor to the newer build or repair the build
from control panel.
Issue: Error message might be displayed in Application Log of event viewer while
restarting the system or service.
Installation Prerequisites
Before installing Dell Command | Monitor, make sure:
You have administrative rights on the client system. This means that you must
be authenticated on the client system as a user who is a member of the
administrators group, typically the administrator.
The target system is a Dell system with SMBIOS version 2.3 or later. Otherwise,
the Dell Command | Monitor installer exits without installing. You can get the
SMBIOS version using the following command in PowerShell: gwmi win32_bios |
select SMBIOSMajorVersion, SMBIOSMinorVersion
The system is running on Microsoft Windows NT based operating systems such
as Windows 10, Windows 8.1, Windows 8, Windows 7 and Windows Vista.
For Windows Vista or later systems, .NET Framework 4.0 or later is installed.
Installation Instructions
For information and procedure for installing Dell Command | Monitor, see the Dell
Command | Monitor Installation Guide, available at
dell.com/dellclientcommandsuitemanuals.
Installation and Configuration Notes
Following an upgrade, it may be necessary to reboot the system for the
installation to complete.