Release Notes
Description: Occasionally ‘Door Open’ indication gets generated due to multiple operations
running at the same time. For example, the BIOS setting are enumerated and configured
continuously in a stress run.
Resolution: Chassis door open indication is repetitive and unless multiple alerts occurs, this should
not be serviced.
NOTE: This behavior is rarely noticed. This issue will be addressed in upcoming release.
Issue: Setting up BIOS configuration may occationally fail.
Description: Failure messages is displayed while a user tries to apply BIOS configurations.
Resolution: Apply BIOS configuration settings again, and it will be successful.
Installation Prerequisites
For systems running Microsoft Windows
Hardware Requirememnts
• Dell Embedded Box PC 3000
• Dell Embedded Box PC 5000
Before installing Dell Command | Monitor, ensure that:
• You have administrative rights on the client system. This means that you must be
authenticated on the client system as a user who is a member of the administrators group,
typically the administrator.
• The target system is a Dell system with SMBIOS version 2.3 or later. Otherwise, the Dell
Command | Monitor installer exits without installing. You can get the SMBIOS version
using the following command in PowerShell command line interface:
get-ciminstance win32_bios | select SMBIOSMajorVersion, SMBIOSMinorVersion
For systems running Linux
Hardware requirements
Operating system
requirements
Prerequisites