Release Notes
Issue: Setting the NonCritical threshold levels for fans is not supported. For the attribute
SettableThreshold the NonCritical value can be set to Settable.
Issue: For temperature probe, the Upper Critical Threshold level should be greater than 0.
Issue: For most of the laptop or desktop platforms, where current reading and the Lower and Upper
Critical values are not defined, the fan health status in the DCIM_NumericSensor class will be
displayed as ‘Critical failure’.
Issue: Digital signatures are missing for some third party files.
Issue: Setting Lower NonCritical Threshold attributes may not be supported although
SupportedThreshold attribute shows that it is supported.
Issue: Previous state attribute in SNMP displays OK for all repetitive alerts.
Issue: If the values of Upper NonCritical Threshold for NumericSensor class are close to reading or
status values, then an event might be generated although the same might not be shown in the class
attributes.
Issue: Enumeration of some classes might not display appropriate values immediately after
upgrade.
Issue: Lower Threshold alerts are not generated; however, they can be monitored using the Current
State attribute in NumericSensor class.
Issue: OID table index in SNMP for most of the traps is 0.
Issue: Degraded status and alert for physical disk is not supported with LSI controllers.
Issue: In LogEntry the element name for alerts is displayed as Alert Log Entry <Alert ID>.