Issue: Configuring OROM UI protection through Dell Command | Monitor results in the
configuration of OROM keyboard access on the following Dell platforms :
Latitude E6x30, E5x30
Dell Precision mobile M4700, M4500
Dell Precision workstation T1650
Optiplex 9010, 7010
Issue: When BIOS password is enabled on a system, you cannot set the attributes Upper and Lower
NonCritical Threshold of the DCIM_NumericSensor class.
Issue: There is no instance for DCIM_videohead class when the System Under Test (SUT)
connecting to High-Definition Multimedia Interface (HDMI) display.
Resolution: You can get this information from Win32_DisplayConfiguration class under
root\cimv2 namespace.
Issue: Peak Shift Start time accepts and sets the value greater than Peak Shift End time. Also Peak
Shift End time accepts and sets the values less than Peak Shift Start time.
Resolution: You can use the Dell Command | Monitor script available in the TechCenter
(http://en.community.dell.com/techcenter/extras/m/mediagallery/20383332.aspx) to set Peak Shift
Configuration. While viewing Intel RAID alerts using DCIM_LogEntry class, severity is reported
as Unknown instead of a Warning message when virtual disk health state is changed to Rebuilding.
Issue: If the fan is not working as indicated by Health Status and OperationalStatus attributes, then
the attribute Current Status will be blank.
Issue: Dynamic Detection of Virtual Disk and Power Supply Unit (PSU) state is not supported.
Issue: No alerts are generated for PSU.