Issue 26: OID table index in SNMP for most of the traps is 0.
Issue 27: Degraded status and alert for physical disk is not supported with LSI
Controllers.
Issue 28: In LogEntry the element name for alerts is displayed as Alert Log Entry <Alert
ID>.
Issue 29: When stopping the data manager service, an error message might be
displayed saying the process cannot be stopped. But the service will be stopped.
Issue 30: The monitoring and alerting status of VirtualDisk with LSI Controllers is
displayed as degraded when the disk is rebuilding.
Issue 31: The Controller Primary state attribute changes to degraded and an alert will
be generated when there is a change in physical or virtual drive in the LSI Controllers.
Issue 32: For LSI Controllers, status or event may not be generated when the Battery
Backup Unit (BBU) is degraded.
Resolution: The BBU degraded status can be viewed in the application log for event (Id
#161 of category type: Warning) generated by source MR_MONITOR.
Installation Prerequisites
•
Before installing Command | Monitor, make sure:
− You have administrative rights on the client system. This means that you must be
authenticated on the client system as a user who is a member of the Administrators
group, typically the Administrator.
− The target system is a Dell system with SMBIOS version 2.3 or later. Otherwise, the
Command | Monitor installer exits without installing.
− One can get the SMBIOS version using the following command in powershell:
gwmi win32_bios | select SMBIOSMajorVersion, SMBIOSMinorVersion