Release Notes
Issue 16: The NonCritical threshold levels for voltage and current cannot be negative
values.
Issue 17: Setting the NonCritical threshold levels for fans is not supported. For the
attribute SettableThreshold the NonCritical value can be set to Settable.
Issue 18: For temperature probe, the Upper Critical Threshold level should be greater
than 0.
Issue 19: For most of the laptop or desktop platforms, where current reading and the
Lower and Upper Critical values are not defined, then the fan health status in the
DCIM_NumericSensor class will be displayed as “Critical failure”.
Issue 20: Digital signatures are missing for some third party files.
Issue 21: Setting Lower NonCritical Threshold attributes may not be supported
although SupportedThreshold attribute shows that it is supported.
Issue 22: Previous state attribute in SNMP displays OK for all repetitive alerts.
Issue 23: If the values of Upper NonCritical Threshold for NumericSensor class are
close to reading or status values, then an event might be generated although the same
might not be shown in the class attributes.
Issue 24: Enumeration of some classes might not return appropriate values
immediately after upgrades.
Issue 25: Lower Threshold alerts are not generated. But they can be monitored using
the Current State attribute in NumericSensor class.