Release Notes
Issue 2: Enumeration of DCIM_ElementCapabilities class results in error
Description: Enumeration of DCIM_ElementCapabilities class returns error through
winrm on a few platforms. WMI studio and Wbemtest works fine.
Resolution: Use WMI studio and WBEMtest tool to enumerate this class.
Issue 3: dsm_sa_datamgr32 service stops responding while installing chipset driver
Description: This issue occurs only when Command | Monitor is installed on some
platforms before installing the chipset driver.
Issue 4: dsm_sa_datamgr service stops responding when USB driver is enabled,
disabled or uninstalled.
Issue 5: Class DCIM_PhysicalDiskView enumerates only IDE disk drives for Intel
Controller.
Issue 6: The value of Link technology property in DCIM_EthernetPort class appears
empty. If the value of any attribute is not in English, then that attribute field may appear
blank or empty. For example, DCIM_EthernetPort_LinkTechnology. DC | M is not
localized and is English language application. However DC | M can be installed on non-
English language versions such as French, German, Spanish, Japanese, Korean,
Simplified Chinese, and Traditional Chinese of supported Windows operating systems.
Issue 7: DC | M allows enabling ‘Secure Boot’ when ‘Legacy Option ROM’ is enabled
and boot mode is UEFI. However, there is no negative impact due to this on the BIOS.
This issue will be addressed in the upcoming BIOS version.
Issue 8: No appropriate message is displayed when Upgrading or Downgrading OMCI.
Downgrading to OMCI 8.0.1 is successful without any message. This is a known issue in
8.0.1 installer. Downgrading to OMCI 8.1 or 8.1.1 is not allowed and a message is
displayed that a prior version has already been installed.