Reference Guide
Property Description
• 32768..65535 = Vendor Reserved
HealthState
Indicates the current health of the element. This
attribute expresses the health of this element but
not necessarily that of its subcomponents.
Possible values are:
• 0 = Unknown — The implementation cannot
report on HealthState now. DMTF has reserved
the unused portion of the continuum for
additional HealthStates in the future.
• 5 = OK — The element is fully functional and is
operating within normal operational parameters
and without error.
• 10 = Degraded/Warning — The element is in
working order and all functionality is provided.
However, the element is not working to the
best of its abilities. For example, the element
may not be operating at optimal performance
or it may be reporting recoverable errors.
• 15 = Minor failure — All functionality is available
but some may be degraded.
• 20 = Major failure — The element is failing. It is
possible that some or all of the functionality of
this component is degraded or not working.
• 25 = Critical failure — The element is
nonfunctional and recovery may not be
possible.
• 30 = Non-recoverable error
• .. = DMTF Reserved — The element has failed,
and recovery is not possible. All functionality
provided by this element has been lost.
IRQLevel
An integer value that represents the IRQ level used
by the serial port.
MaxSpeed
The maximum bandwidth of the Port in Bits per
Second.
OperationalStatus
Indicates the current statuses of the element.
Various operational statuses are defined. Many of
the enumeration's values are self-explanatory.
However, a few are not and are described here in
more detail.
Possible values are:
• 0 = Unknown
• 1 = Other
• 2 = OK
• 3 = Degraded
• 4 = Stressed — Indicates that the element is
functioning, but needs attention. Examples of
Stressed states are overload, overheated, and
so on.
89