Reference Guide
Attribute Name Description
Attribute names for Set operation:
• Peak Shift Sun StartHour
• Peak Shift Sun StartMin
• Peak Shift Sun EndHour
• Peak Shift Sun EndMin
• Peak Shift Sun ChargeStartHour
• Peak Shift Sun ChargeStartMin
NOTE: To use Peak Shift mode, the values of Peak Shift Start
Time, Peak Shift End Time, Peak Shift Charge Start Time, and
Peak Shift battery threshold are necessary.
NOTE: It is recommended to input values as per the following:
Start Time <= End Time <= Charge Start Time. Command |
Monitor can set the out-of-range values. BIOS behavior is
unknown at this point of time for such values.
NOTE: The values defined for Minute field are 0,15,30 and 45. In
case you set any other value, the value is round to the lower
defined value.
Peak Shift Mon
This attribute configures the power usage configuration for Monday.
Possible values are:
• 0 — 23 — Start Hour
• 0 — 59 — Start Minute
• 0 — 23 — End Hour
• 0 — 59 — End Minute
• 0 — 23 — Charge Start Hour
• 0 — 59 — Charge Start Min
Attribute names for Set operation:
• Peak Shift Mon StartHour
• Peak Shift Mon StartMin
• Peak Shift Mon EndHour
• Peak Shift Mon EndMin
• Peak Shift Mon ChargeStartHour
• Peak Shift Mon ChargeStartMin
Peak Shift Tue
This attribute configures the power usage configuration for Tuesday.
Possible values are:
• 0 – 23 — Start Hour
• 0 — 59 — Start Minute
• 0 — 23 — End Hour
• 0 — 59 — End Minute
• 0 — 23 — Charge Start Hour
• 0 — 59 — Charge Start Min
Attribute names for Set operation:
322