Reference Guide
Property Description
PendingPowerUtilizationAlgorit
hm
This property describes the pending requested algorithm to be
employed by the service for power utilization.
Possible values are:
• 0 = Unknown
• 2 = None — Indicates that currently the service is not employing
any power utilization algorithm. If the property value is 2 (None),
then the PowerUtilizationMode is equal to 2 (None).
• 3 = Custom Settings Based — Indicates that the service is
employing power utilization algorithm based on a specific
settings. This settings may be represented by the
DCIM_PowerUtilizationSettingData instance associated
• 4 = Maximum Performance — Indicates that the service is
employing a power utilization that yields the maximum
performance for the affected managed elements. If the property
value is 4 (Maximum Performance), then the
PowerUtilizationMode is equal to 4 (Static).
• 5 = Minimum Performance — Indicates that the service is
employing a power utilization that yields the minimum power
consumption for the affected managed elements. If the property
value is 5 (Minimum Performance), then the
PowerUtilizationMode is equal to 4 (Static).
• 6 = OS Specific — Indicates that the service is employing a power
utilization defined by the operating system. If the property value is
6 (OS Specific), then the PowerUtilizationMode is equal to 3
(Dynamic).
• 7 = Active Power Utilization — Indicates that the service is
employing a specific algorithm to yield the best power
conumption and performance for the affected managed
elements. If the property value is 7 (Active Power Utilization),
then the PowerUtilizationMode is equal to 3 (Dynamic).
PowerUtilizationAlgorithm
Describes the algorithm employed by the service for power
utilization. Depending on the performance and power needs of the
managed element, the selection could be made for the appropriate
algorithm to be deployed for the power utilization.
Possible values are:
• 0 = Unknown(Dynamic).
• 2 = None — Indicates that currently the service is not employing
any power utilization algorithm. If the property value is 2 (None),
then the PowerUtilizationMode is equal to 2 (None).
• 3 = Custom Settings Based — Indicates that the service is
employing power utilzation algorithm based on a specific settings.
This settings may be represented by the
DCIM_PowerUtilizationSettingData instance associated
• 4 = Maximum Performance — Indicates that the service is
employing a power utilization that yields the maximum
performance for the affected managed elements. If the property
value is 4 (Maximum Performance), then the
PowerUtilizationMode is equal to 4 (Static).
• 5 = Minimum Performance — Indicates that the service is
employing a power utilization that yields the minimum power
consumption for the affected managed elements. If the property
value is 5 (Minimum Performance), then the
PowerUtilizationMode is equal to 4 (Static).
• 6 = OS Specific — Indicates that the service is employing a power
utilization defined by the operating system. If the property value is
193