Issue: Setting the NonCritical threshold levels for fans is not supported. For the attributes SettableThreshold the NonCritical value can be
set to Settable.
Issue: For temperature probe, the Upper Critical Threshold level should be greater than 0.
Issue: Digital signatures are missing for some third party files.
Issue: Setting Lower NonCritical Threshold attributes may not be supported although SupportedThreshold attributes shows that it is
supported.
Issue: If the values of Upper NonCritical Threshold for NumericSensor class are close to reading or status values, then an event might be
generated although the same might not be shown in the class attributes.
Issue: Lower Threshold alerts are not generated; however, they can be monitored using the Current State attributes in NumericSensor
class.
Issue: Degraded status and alert for physical disk is not supported with LSI controllers.
Issue: In LogEntry the element name for alerts is displayed as Alert Log Entry <Alert ID>.
Issue: While stopping the data manager service, an error message might be displayed saying the process cannot be stopped. But the
service will be stopped.
Issue: For LSI controllers, status or event may not be generated when the Battery Backup Unit (BBU) is degraded.
Resolution: The BBU degraded status can be viewed in the application log for event (Id #161 of category type: Warning) generated by
source MR_MONITOR.
Issue: After upgrading from Windows OS, enumerating WMI classes may not display appropriate results.
Resolution: Reinstall Dell Command | Monitor to the newer build or repair the build from control panel.
Issue: Error message might be displayed in Application Log of event viewer while restarting the system or service.
Issue: Hyper-v does not work
Description: Hyper-v doesn’t work if Dell Command | Monitor is installed for the first time on clean installation of Windows 10.
Resoultion: Rebuild Hyper V WMI repository by executing the command:
MOFCOMP <SYSTEMROOT>\System32\WindowsVirtualization.V2.mof
Issue: DCIM_Docked class displays value Unknown for ElementName property.
Issue: HAPI driver shipped with Dell Command | Monitor version 10.1 and 10.0 complies with Windows Hardware Quality Labs (WHQL) for
Windows 10. A security message is displayed while installing Dell Command | Monitor on any other Windows operating systems.
Resolution: Upgrade to latest Dell Command | Monitor.
Issue:After the setup password has been set in DINO-XPS-Win7 or any other platform, then those platforms does not allow you to set
the system password.
Issue: Windows failed to initiate DSM Data Manager service on a local computer.
Resolution: Visual C++ Re-distributable for Visual Studio 2015 must be installed.