Reference Guide

Property Description Supported
Operating
System(s)
If knowledge of the last RequestedState is not supported for the EnabledLogicalElement,
the property is NULL or has the value 12 Not Applicable.
Possible values are:
0 = Unknown — Indicates the last requested state for the element is unknown.
2 = Enabled
3 = Disabled
4 = Shut Down
5 = No Change
6 = Oine
7 = Test
8 = Deferred
9 = Quiesce
10 = Reboot — Refers to doing a Shut Down and then moving to an Enabled state.
11 = Reset — Indicates that the element is rst Disabled and then Enabled.
12 = Not Applicable
.. = DMTF Reserved
32768..65535 = Vendor Reserved
SensorType
The Type of the Sensor, e.g. Voltage or Temperature Sensor. If the type is set to Other,
then the OtherSensorType Description can be used to further identify the type, or if the
Sensor has numeric readings, then the type of the Sensor can be implicitly determined by
the Units. A description of the dierent Sensor types is as follows: A Temperature Sensor
measures the environmental temperature. Voltage and Current Sensors measure electrical
voltage and current readings. A Tachometer measures speed/revolutions of a Device. For
example, a Fan Device can have an associated Tachometer which measures its speed. A
Counter is a general purpose Sensor that measures some numerical property of a Device. A
Counter value can be cleared, but it never decreases. A Switch Sensor has states like
Open/Close, On/O, or Up/Down. A Lock has states of Locked/Unlocked. Humidity,
Smoke Detection and Air Flow Sensors measure the equivalent environmental
characteristics. A Presence Sensor detects the presence of a PhysicalElement. A Power
Consumption Sensor measures the instantaneous power consumed by a managed
element. A Power Production Sensor measures the instantaneous power produced by a
managed element such as a power supply or a voltage regulator. A pressure sensor is used
to report pressure. Intrusion sensor reports an intrusion of an enclosure regardless whether
it was authorized or not.
Possible values are:
0 = Unknown
1 = Other
2 = Temperature
3 = Voltage
4 = Current
5 = Tachometer
6 = Counter
7 = Switch
8 = Lock
9 = Humidity
10 = Smoke Detection
11 = Presence
12 = Air Flow
13 = Power Consumption
14 = Power Production
15 = Pressure
Microsoft
Windows, Linux
Dell Command | Monitor10.1.0 classes and properties 127