Release Notes
Table Of Contents
Load the module by running the following command:
insmod <filename>
● Windows 7 does not recognize the digital signature validity. If the system is not connected to internet, Windows 7 does not
recognize the digital signature validity of Dell Command | Configure installation file.
Connect the system to the internet, and validate the digital signature.
● Dell Command | Configure does not support infile or outfile options in the .ini file.
● Dell Command | Configure supports only single-byte characters for an asset set operation.
If the user has a different locale, change the keyboard layout to English before using the asset option.
● Dell Command | Configure does not control the dependencies among the various TPM PPI options. For example, it is possible
to change the TPM PPI ACPI option through Dell Command | Configure even when TPM is not On.
NOTE: There is no negative impact due to this on the BIOS.
● Dependent options are not working as configured in UEFI mode for Legacy Option ROM and Secure Boot.
Description:
○ Dell Command | Configure allows enabling Legacy Option ROM when Secure Boot is On. If the Secure Boot is Off, then
the Dell Command | Configure does not allow you to enable the Legacy Option ROM configuration.
○ Dell Command | Configure allows disabling Legacy Option ROM when Boot mode is Legacy. If the Boot Mode is not
Legacy, then the Dell Command | Configure does not allow you to disable the Legacy Option ROM.
○ Dell Command | Configure allows enabling Secure Boot when Legacy option ROM is enabled and boot mode is UEFI. If
the Legacy option ROM is disabled and boot mode is Legacy, then the Dell Command | Configure disables the Secure
Boot.
○ Dell Command | Configure does not allow enumerating Secure Boot when it is disabled. If the Secure Boot is enabled,
then the boot options can be enumerated.
NOTE: There is no negative impact due to this on the BIOS. This issue is addressed in the upcoming BIOS versions.
● Blinkpsu1led and Blinkpsu2led is missing in the .ini file or SCE. Blinkpsu1led and Blinkpsu2led are not been present in the .ini
file or SCE as they are enable-only tokens and they are active only for few seconds. These tokens cannot be modified using
user interface.
● advsm option displays the status as Other. If any of the fans are not working, the advsm option displays the status as
Other.
● Advance Battery Charge and Peak Shift Charge options are displayed as Disable. The system displays the option as Disable
for the platforms which does not support battery charge.
The system displays the option as Disable, when the peakshiftcfg option is enumerated.
● Temperature probe in Advanced System Management option displays as Unknown. On some platforms that support
Advanced System Management option, temperature probe of all the sensors displays as Unknown
NOTE: This issue is addressed in the upcoming BIOS versions.
● On some of the platforms that support Advanced System Management option, temperature probe of memory sensor 2
displays the current status as Non-Critical instead of Normal.
NOTE: This issue is addressed in the upcoming BIOS versions.
● On some of the platforms that support Advanced System Management option, when you set noncritical upper threshold
values for cooling device, the CLI indicates that the action failed; however, setting the same is successful.
● Windows Camera is unavailable for two milliseconds, while running the Dell Command | Configure SCE or importing .ini file.
● A warning message is not displayed for BootOrder while enabling and disabling the same device. Dell Command Configure
does not display any warning messages when you try to enable or disable the same bootable device.
Example: cctk bootorder --bootlisttype=uefi --EnableDevice=hdd.1,hdd.2 --DisableDevice=hdd.1,hdd.2
If the current status of the device is enabled, then the same device is disabled or vice versa.
● If Dell Command | Monitor 10.2 and Dell Command | Configure 4.1 (or any prior versions) are installed in a system, then the
Dell Command | Configure 4.1 (or any prior versions) may not work.
● After the setup password has been set in XPS 9300, Dell Precision 7700, and Dell Precision 7500 series platforms, these
platforms does not allow you to set the system password.
● If you run SCE in Windows 7 operating system, Program Compatibility Assistant error is displayed periodically.
10
Dell Command | Configure Version 4.4