Reference Guide
Attribute Details Description
• Adaptive — Charges the battery based on a periodic evaluation of battery usage to deliver the
best balance capacity.
• Custom — The battery charging starts and stops based on user input. The start value range
should be 50-95 percent, the stop value range should be 55-100 percent, and the difference
between the start and stop values should be greater than or equal to 5.
Example
C:\>cctk --PrimaryBattChargeCfg=Standard
PrimaryBattChargeCfg=Standard
C:\>cctk --PrimaryBattChargeCfg=Custom:50-70
PrimaryBattChargeCfg=Custom:50-70
NOTE: The format to set custom option is custom:start value-stop value. The
start value range must be 50–95 percentage and the stop value range must be 55–100
percentage. The difference between the start and stop values must be greater than or
equal to 5.
--PrimaryVideoSlot
Table 338. --PrimaryVideoSlot
Attribute Details Description
Valid Argument Auto, Slot0, Slot1, Slot2, Slot3, Slot4, Slot5, Slot6, Slot7, Slot8, Slot9, Slot10, Slot11, Slot12, Slot13,
Slot14, Slot15Onboard
Configuring the slot for Primary video display.
• Onboard — Sets the onboard video device slot as primary video device slot.
• Auto — Scans PCI buses and uses the first video device slot found with video card as a primary
video device slot.
• Slot0-Slot15 — Sets the specified slot number as a primary video device slot.
NOTE: If a video card is not available in the specified slot number, the system will scan
the PCI buses and uses the first video device slot found with video card as a primary
video device.
Example
C:\>cctk --PrimaryVideoSlot=Auto
PrimaryVideoSlot=Auto
--PrimIdeMast
Table 339. --PrimIdeMast
Attribute Details Description
Valid Argument Auto, Off
Enables or disables primary IDE master channel.
--PrimIdeSlav
Table 340. --PrimIdeSlav
Attribute Details Description
Valid Argument Auto, Off
Enables or disables primary parallel IDE slave channel.
96 Options for Dell Command | Configure 4.3