Reference Guide

If the system has a setup password, while setting the non-critical threshold values specify the setup password and set the non-
critical threshold values as:
cctk advsm --set=<option name>:<upper non critical threshold value> --valsetuppwd= <setup
password>
For example, to set the non-critical threshold values for a voltage probe on a system with a setup password, type:
cctk advsm --set=voltage_1:55 --valsetuppwd = <setup password>
For example, to set the non-critical threshold values for a current probe on a system with a setup password, type:
cctk advsm --set=current_1:55 --valsetuppwd = <setup password>
For example, to set the non-critical threshold values for a cooling probe on a system with a setup password, type:
cctk advsm --set=cd_1:55 --valsetuppwd = <setup password>
For example, to set the non-critical threshold values for a temperature probe on a system with a setup password, type:
cctk advsm --set=temperature_1:55 --valsetuppwd = <setup password>
If the system has a system password and no setup password, while setting the non-critical threshold values specify the system
password and set the non-critical threshold values as:
cctk advsm --set=<cctk option name>:<upper non critical threshold value> --valsyspwd=
<system password>
For example, to set the non-critical threshold values for a voltage probe on a system with a system password and no setup
password, type:
cctk advsm --set=voltage_1:10 --valsyspwd = <system password>
For example, to set the non-critical threshold values for a current probe on a system with a system password and no setup
password, type:
cctk advsm --set=current_1:10 --valsyspwd = <system password>
For example, to set the non-critical threshold values for a cooling probe on a system with a system password and no setup
password, type:
cctk advsm --set=cd_1:10 --valsyspwd = <system password>
For example, to set the non-critical threshold values for a temperature probe on a system with a system password and no setup
password, type:
cctk advsm --set=temperature_1:10 --valsyspwd = <system password>
PCI reporting
The scan of the PCI bus will use a file to resolve PCI vendor and device codes to vendor information strings. The format of the PCI
output is as follows:
PCI Bus: 2, Device: 4, Function: 0
Vendor: 8086 - Intel Corp.
Device: 1229 - 82557/8/9 [Ethernet Pro 100]
Sub Vendor:8086 - Intel Corp.
Sub Device:1017 - EtherExpress PRO/100+ Dual Port Server Adapter
Slot: 01
Class: 02 - Network
SubClass: 00 - Ethernet
If the file for vendor resolution is not present, the utility will print Unknown next to a vendor name. If the file for environment
variable names is not present, the utility will fail the environment variable operation.
The pci.ids file is located at :
Systems running on supported Windows operating system:
91