Release Notes

Issue description: On some of the platforms that support Advanced System
Management option, when you set non-critical upper threshold values for cooling
device, the CLI indicates that the action failed; however, setting the same will be
successful.
Issue: Autoon minutes (autoonmn) is listed in the do not edit section in the .ini file
Description: The .ini file is exported from the CLI contains autoonmn option in do not
edit section; however, this option can be configured when such .ini files are imported.
Issue: Not able to configure ASM (advsm) BIOS options in .ini file/SCE
Description: While configuring ASM (advsm) option using .ini file, or SCE, Setup
password or System password should not be set or modified.
GUI
Issue: The GUI takes loger to launch in OptiPlex 990 and Latitude D630
Description: When you launch Dell Command | Configure GUI from OptiPlex 990 and
Latitude D630 without administrator privileges, the GUI screen takes some time to
appear. NOTE: This does not hamper the system resources and Dell Command |
Configure will be functional.
Issue description: On Dell Precision workstation M4400, the bootorder option may
not display the correct number of boot devices.
Issue: Unexpected Error at System.xml.
Description: Dell Command | Configure GUI supports only printable characters for its
text-entry fields. If the BIOS has non-printable characters, the GUI may fail to load and
display the following error message: Unexpected Error at System.xml.
Resolution: Make sure that BIOS options such as asset, and propowntag values do not
contain non-printable characters.