Technical Specifications
Table Of Contents
- Dell EMC PowerEdge R550 Technical Specifications
- Contents
- Technical specifications
- Chassis dimensions
- Chassis weight
- Processor specifications
- PSU specifications
- Supported operating systems
- Cooling fan specifications
- System battery specifications
- Expansion card riser specifications
- Memory specifications
- Storage controller specifications
- Drives
- Ports and connectors specifications
- Environmental specifications
PCIe adapter cards and other slot restrictions
● Can support Mellanox CX6-DX with Finisar 100G QSFP28 optical transceiver for all the slots.
● Mellanox Starlord CX6 Dx DP 100GbE with QSFP56 (MFS1S00-V003E) restricted to slot1, slot3 and slot6 in all the
configurations.
Table 23. Processor and heat sink matrix
Heat sink Processor TDP
2U STD HSK < 165 W
2U HPR HSK >= 165 W
ASHRAE A3 and A4 environment thermal restriction
● Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced.
● Processor TDP greater than or equal to 185 W are not supported.
● Front storage is not supported in 12x3.5-inch SAS/SATA configuration.
● Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
● OCP transceiver specification greater than or equal to 70°C is not supported.
● OCP card with transmission rate greater than 25 GB is not supported.
● PCIe SSD is not supported.
● BOSS (M.2) card is not supported.
12
Technical specifications