Users Guide

The object is displayed in the selected object pane.
9. Choose the event severity to generate a report.
10. Click Run to generate the Windows Event Log report.
Customizing the Dell Client Management Pack
You can customize the following components of the Dell Client Management Pack by using overrides to increase or decrease the intervals
to the specific Dell hardware management needs of the OpsMgr operator.
Monitors — Assesses various conditions that can occur in monitored objects. The result of this assessment determines the health
state of a target and the alerts that are generated.
Object Discoveries — Discovers objects on a network that requires monitoring.
Rules — Collects data, such as events generated by managed objects.
Unit monitors
The following table provides information about the various Dell unit monitors and the applicable parameters for client systems:
Table 7. Dell unit monitors in Dell Client Management Pack
Groups Unit Monitor Name Default Periodic Poll Setting
DCM/OMCI Service Instance Periodic 3600 seconds
(60 minutes)
Memory Group for Dell Client Periodic 3600 seconds
(60 minutes)
Processor Group for Dell Client Periodic 3600 seconds
(60 minutes)
Processor Unit Instance Periodic 3600 seconds
(60 minutes)
Sensors of Dell client systems
Battery
Battery Charging status
Battery Health status
Current
Fan
Intrusion
Temperature
Voltage
Periodic 3600 seconds
(60 minutes)
Storage Group for Dell Client Periodic 3600 seconds
(60 minutes)
Disk Unit Instance Periodic 3600 seconds
(60 minutes)
NOTE:
When chassis door is removed or closed, Dell Command | Monitor or OMCI generates Chassis Intrusion events. For
more information about enabling, disabling, and clearing Chassis Intrusion events, see System Setup (BIOS) in the
Owner's Manual
of the Dell client system.
Monitoring for memory is available at the Group level only.