Known issues—To be xed in future releases
On few Dell Client platforms, health status does not change to normal after the Dell Client recovers from the Fan Probe error
Description: On R5400, T7400 and OptiPlex 390 systems, health status does not change to normal after the Dell Client recovers from Fan
Probe error.
Workaround: Reboot the Dell Client to clear the status of the Fan probe.
Tracking number: Not applicable
When an additional battery is added to the Dell client, the battery part number of the added battery is not discovered
Description: On Dell client laptops that support multiple batteries, when an additional battery is added, the battery part number for the
added battery is not discovered in the subsequent discovery cycles.
Workaround: Reboot the laptop.
Tracking number: Not applicable
Chassis intrusion health status does not change even after chassis is removed
Description: On OptiPlex 990(with bios: A05) and 390(with bios: A01), Chassis intrusion health status does not change even after chassis
is removed. BIOS does not support such events, and hence the OMCI does not expose this health for the above platforms. As a result,
Client Management Pack shows the components as healthy.
Workaround: Upgrade to latest BIOS version.
Tracking number: Not applicable
FAN health status does not change even after the FAN has stopped
Description: On few Client platforms, FAN health status may not change even if fan stops, and the status remains unchanged even after
rebooting the client system.
Workaround: No known workaround
Tracking number: Not applicable
MP Knowledge Base is not displayed on I18N Management Stations
Description: On OpsMgr MS with non-English locale, the Client Management Pack does not display MP Knowledge Base text.
Workaround: No known workaround
Tracking number: Not applicable