Owner's Manual
Issue 3
- 499881: Chassis intrusion health status in not changing even after chassis is removed.
Description:
On OptiPlex 990(with bios: A05) and 390(with bios: A01), Chassis intrusion health status in not changing even after chassis is
removed. BIOS does not have support for these events and hence the OMCI does not expose this health for the above
platforms. As a result, Client MP shows the components as healthy.
Resolution:
Upgrade to latest BIOS version.
Issue 4
- 501257: FAN health status in not changing even after FAN is stopped
Description:
On few Client platforms, FAN health status may not change if fan stops and the status remain unchanged even after the
reboot of client system.
Resolution:
No known workaround.
Issue 5
- 045713: MP Knowledge Base is not displayed on I18N Management Stations
Description:
On OpsMgr MS with non-English locale, the Client Management Pack does not display MP Knowledge Base text.
Resolution: