Issue 5 - DF487533: Few attributes value of Dell Client are shown as empty when OMCI is downgraded from OMCI 8.0
to OMCI 7.8
Description
After downgrading OMCI from 8.0/8.0.1 to 7.8, you may see few attributes value of Dell Client shown as empty. These
attributes are model type, asset tag, service tag, bios version and manufacture ship date.
Resolution
Restart the Dell Client after downgrading OMCI from 8.0 to 7.8.
Versions Affected
Microsoft System Center Operations Manager (SCOM) 2007 SP1/R2, System Center Essentials (SCE) 2007 SP1/2010 and OMCI
7.8
Issue 6 - DF499508: When an additional battery is added to the Dell Client, the battery part number for the added
battery is not discovered.
Description
On Dell Client Laptops that support multiple batteries, when an additional battery is added, the battery part number for the
added battery is not discovered in the subsequent discovery cycles.
Resolution
Reboot the Laptop.
Versions Affected
Microsoft System Center Operations Manager (SCOM) 2007 SP1/R2, System Center Essentials (SCE) 2007 SP1/2010
Issue 7 - DF499881: Chassis intrusion health status does not change even after chassis is removed.
Description
On Optiplex 990(with bios: A05) and 390(with bios: A01), Chassis intrusion health status does not change even after chassis
is removed. BIOS do not have support these events and hence the OMCI does not expose these health for the above
platforms. As a result, Client Management Pack shows the components as healthy.
Resolution
No known resolution.
Versions Affected
Microsoft System Center Operations Manager (SCOM) 2007 SP1/R2, System Center Essentials (SCE) 2007 SP1/2010 and OMCI
8.0.1
Platforms Affected
•
Optiplex 990(bios: A05)
•
390(bios: A01)
•
Precision T1600(bios: A01)