Users Guide
CCTK Options 63
Description
Enables or disables the second embedded NIC.
Example
C:\>cctk --embnic2=on
embnic2=on
--embraidchannelaprimarycopy
Valid Argument
raid, scsi
Description
Sets the channel A of the embedded RAID controller to operate in RAID
or SCSI mode when the system boots the next time.
NOTE: The setting is valid only if the embedded RAID controller is set to RAID
mode.
Example
C:\>cctk --embraidchannelaprimarycopy=raid
embraidchannelaprimarycopy=raid
--embraidchannelbprimarycopy
Valid Argument
raid, scsi
Description
Sets the channel B of the embedded RAID controllerto operate in RAID or
SCSI mode when the system boots the next time.
NOTE: The setting is valid only if the embedded RAID controller is set to RAID
mode.
Example
C:\>cctk --embraidchannelbprimarycopy=raid
embraidchannelbprimarycopy=raid