Setup Guide

Configuring Storage 57
Fully Redundant
— This configuration contains XenServer hosts, each
with two NICs (bonded to provide high availability) for iSCSI connectivity
and a PS Series enclosure with redundant RAID controllers. One of each
host's NICs is connected to Ethernet switch 0, while the second of each
host's NICs is connected to Ethernet switch 1. The two Ethernet switches
are connected by two Inter Switch Links (ISLs). Ethernet switch 0 has
connections to two ports on RAID controller 0 and one connection to
RAID controller 1. Ethernet switch 1 has connections to two ports on
RAID controller 1 and one connection to RAID controller 0. See
Figure 5-21 for an illustration of this configuration.
Storage repositories on a XenServer host or a XenServer pool can be
created on the iSCSI volumes on the EqualLogic array.
NIC0
and
NIC1
XenServer host are bonded to provide high availability for the iSCSI
storage traffic. This configuration provides redundancy against host NIC,
switch, or array controller failure.
Figure 5-21. PS Series – Fully Redundant
XenServer Host(s)
Redundant Ethernet
Switches
NIC 0
NIC 0
LAN
NIC 1
NIC 1
ISL
Dell EqualLogic
PS5000 Series Array