Setup Guide

28 Systems Management Using Dell OpenManage
You can also upload the update package to the XenServer host using a file
transfer program and then run the package. Log in to the XenServer host as a
root user and perform the following steps:
1
Upload the update package (*.BIN file) to
/var/tmp
.
2
Login to the XenServer local console shell.
3
Run the
BIN
file that you downloaded.
4
Follow the instructions provided by the update package.
5
Reboot the system if required by the update package.
For more information on using Dell Update Package with ITA, see the
Dell OpenManage ITA documentation available on the Dell Support
website at support.dell.com/manuals.
Using the Racadm Command
Run the racadm command, normally found at /usr/sbin/racadm, from the
following locations, depending on the type of PowerEdge system:
Run the
racadm
command from
/opt/dell/srvadmin/rac5/bin/racadm
if you have one of the following systems: PowerEdge 2950-iii,
PowerEdge 1950-iii, PowerEdge 2900-iii, PowerEdge R805,
PowerEdge R900 or PowerEdge R905.
Run the
racadm
command from
/opt/dell/srvadmin/idrac/bin/racadm
if
you have one of the following systems: PowerEdge M600, PowerEdge M605,
PowerEdge M805, PowerEdge M905, PowerEdge R710, PowerEdge R610,
PowerEdge T610, PowerEdge T710, PowerEdge M610 or PowerEdge M710.