Users Guide

Configuring Services Using CMC Web Interface
To configure CMC services using CMC Web interface:
1. In the system tree, go to Chassis Overview, and then click Network > Services. The Services page is displayed.
2. Configure the following services as required:
CMC serial console
Web server
SSH
Telnet
Remote RACADM
SNMP
Remote Syslog
For information about the fields, see CMC Online Help.
3. Click Apply, and then update all default time outs and maximum time out limits.
Configuring Services Using RACADM
To enable and configure the various services, use the following RACADM objects:
cfgRacTuning
cfgRacTuneRemoteRacadmEnable
For more information about these objects, see Chassis Management Controller for Dell PowerEdge M1000e RACADM Command Line
Reference Guide available at dell.com/support/manuals.
If the firmware on the server does not support a feature, configuring a property related to that feature displays an error. For example,
using RACADM to enable remote syslog on an unsupported iDRAC displays an error message.
Similarly, when displaying the iDRAC properties using the RACADM getconfig command, the property values are displayed as N/A for an
unsupported feature on the server.
For example:
$ racadm getconfig -g cfgSessionManagement -m server-1
# cfgSsnMgtWebServerMaxSessions=N/A
# cfgSsnMgtWebServerActiveSessions=N/A
# cfgSsnMgtWebServerTimeout=N/A
# cfgSsnMgtSSHMaxSessions=N/A
# cfgSsnMgtSSHActiveSessions=N/A
# cfgSsnMgtSSHTimeout=N/A
# cfgSsnMgtTelnetMaxSessions=N/A
# cfgSsnMgtTelnetActiveSessions=N/A
# cfgSsnMgtTelnetTimeout=N/A
Configuring CMC Extended Storage Card
You can enable or repair the optional Removable Flash Media for use as an extended non-volatile storage. Some CMC features depend on
extended nonvolatile storage for their operation.
To enable or repair the Removable Flash Media using the CMC Web interface:
1. In the System tree, go to Chassis Overview, and then click Chassis Controller > Flash Media. The Removable Flash Media page is
displayed.
2. From the drop-down menu, select one of the following as required:
Use flash media for storing chassis data
Repair active controller media
Begin replicating data between media
Stop replicating data between media
Stop using flash media for storing chassis data
For more information about these options, see the CMC Online Help.
3. Click Apply to apply the selected option.
Configuring CMC
77