Users Guide

The following figure shows the QuickDeploy IP addresses assignment to the servers when there are 16 half height severs in a M1000e
chassis:
The following figure shows the QuickDeploy IP addresses assignment to the servers when there are 32 quarter height severs in a M1000e
chassis:
Configuring Reserved QuickDeploy IP Addresses Using RACADM
To modify the number of static IP addresses allocated for servers on the chassis using RACADM, use the following command:
racadm deploy –q -n <num>
where <num> is the number of IP addresses, 8. 16, or 32.
To view current settings for the number of reserved IP addresses and the Use CMC DNS Settings for servers on the chassis using
RACADM, use the following command:
racadm deploy –q
To modify the Use the CMC DNS Settings option to enable quick deploy for servers on the chassis using RACADM, use the following
command:
racadm deploy -q -e <enable/disable>
For more information, see the Chassis Management Controller for Dell PowerEdge M1000e RACADM Command Line Reference Guide
available at dell.com/support/manuals.
Modifying iDRAC Network Settings for Individual Server
iDRAC
Using this table you can configure the iDRAC network configurations settings for each installed server. The initial values displayed for each
of the fields are the current values read from the iDRAC.
To modify the iDRAC Network Settings using the CMC Web interface:
1. In the system tree, go to Server Overview, and then click Setup > iDRAC. The Deploy iDRAC page is displayed. The iDRAC
Network Settings section lists the iDRAC DNS name, IPv4, and IPv6 network configuration settings of all the installed servers.
2. Modify the iDRAC network settings as required for the servers.
NOTE:
You must select the Enable LAN option to specify the IPv4 or IPv6 settings. For information about the fields,
see CMC Online Help.
3. To deploy the setting to iDRAC, click Apply iDRAC Network Settings. If you made changes to the QuickDeploy settings, they are
also saved.
The iDRAC Network Settings table reflects future network configuration settings; the values shown for installed servers may or may
not be the same as the currently installed iDRAC network configuration settings. Click Refresh to update the iDRAC Deploy page
with each installed iDRAC network configuration settings after changes are made.
NOTE:
Changes made to QuickDeploy fields are immediate, but changes that are made to one or more iDRAC server
network configuration settings may require a couple of minutes to propagate from CMC to iDRAC. Clicking Refresh
too soon may display only partially correct data for a one or more iDRAC servers.
100 Configuring Server