Users Guide
表. 48: 电源更改的 SEL 事件 (续)
电源事件
系统事件日志 (SEL) 条目
DC output under-current(直流输出电流过低) An output under current fault detected on power supply <number>.(在电源设
备 <number> 上检测到输出电流过低故障。)
Communication failure(通信故障) Cannot communicate with power supply <number>.(无法与电源设备
<number> 通信。)
Communication restored(通信已还原) Communication has been restored to power supply <number>.(与电源设备
<number> 的通信已还原。)
Failure to communicate status data(无法传送状态
数据)
Cannot obtain status information from power supply <number>.(无法从电源设
备 <number> 获取状态信息。)
Status data communication restored(状态数据通信
已还原)
Power supply <number> status information successfully obtained.(已成功获取
电源设备 <number> 的状态信息。)
Over/Under-temperature(温度过高/过低) The temperature for power supply <number> is outside of range.(电源设备
<number> 的温度超出允许范围。)
Fan or Airflow error/warning(风扇或气流错误/警
告)
Fan failure detected on power supply <number>.(在电源设备 <number> 上检
测到风扇故障。)
Fan speed overridden(风扇速度超限) Fan failure detected on power supply <number>.(在电源设备 <number> 上检
测到风扇故障。)
Manufacturing fault(制造故障) Power supply <number> failed.(电源设备 <number> 故障。)
Microprocessor busy(微处理器正忙) Power supply <number> failed.(电源设备 <number> 故障。)
FRU error(FRU 错误) Power supply <number> failed.(电源设备 <number> 故障。)
Unacknowledged 110V operation detected(检测到未
认可的 110V 工作状态)
Power supply low input voltage (110) was asserted.(电源设备输入低压 (110)
已确认。)
110V operation acknowledged(110V 工作状态认可) Power supply low input voltage (110) was de-asserted.(电源输入低压 (110) 已
解除确认。)
与电源冗余状态变化相关并记录在 SEL 中的事件包括:冗余丢失以及冗余重新获得,这适用于配置为电网冗余电源策略或电源设备
冗余电源策略的模块化机柜。下表列出有关电源冗余策略更改的 SEL 条目。
表. 49: 电源冗余策略更改的 SEL 事件
电源策略事件
系统事件日志 (SEL) 条目
冗余丢失
Redundancy lost was asserted(冗余丢失已确认)
冗余恢复
Redundancy lost was de-asserted(冗余丢失已解除确认)
配置电源预算和冗余
您可以配置整个机箱(机箱、服务器、I/O 模块、iKVM、CMC 和电源设备)的电源预算、冗余和动态电源,整个机箱使用六个电源
设备 (PSU)。电源管理服务可优化电源,并根据需要为不同模块重新分配电源。
您可以配置以下各项:
● 系统输入功率上限
● 冗余策略
● 扩展电源性能
● 服务器性能优先于电源冗余
● 动态电源设备接入
● 禁用机箱电源按钮
● 允许 110 V 交流操作
● 最大节能模式
● 远程电源日志记录
● 远程电源日志记录间隔
194