Release Notes
Known Issues
Flex disabled address after racresetcfg of CMC
Description XWKGY_Intel10G card shows Flex disabled address after racresetcfg of CMC in the Network Device page
and OS.
Resolution Virtual reseat or physical reseat of the server.
Versions/Systems
affected
All CMC versions including CMC 6.10 and the PowerEdge servers with iDRAC7 or earlier.
Error occurs while importing CMC configuration
file
Description An error occurs while importing CMC configuration file using local or remote RACADM.
Resolution This issue occurs when IPv6 is enabled or disabled from the configuration file. Enable or disable IPv6 using the
command, racadm config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0.
Versions/Systems
affected
CMC version 5.11 or later
Server components update page gets corrupt
Description
When CMC firmware is downgraded to 4.50 from 5.00 or later while network share is configured, the Server
Components Update page gets corrupt.
Resolution Clear the network configuration before downgrading to 4.50.
Versions/Systems
affected
CMC version 4.50 or earlier
Unable to view chassis logs from remote RACADM
Description
Unable to view chassis logs from remote RACADM
Resolution None
Use firmware RACADM instead, to view the chassis logs.
Versions/Systems
affected
All CMC versions including 6.20 using OM 911 and later.
Tracking number 109003
Static IPv6 IP address can be assigned to iDRAC
blades
Description
Static IPv6 IP address can be assigned to iDRAC blades using RACADM deploy command even when the IPv6
interface of iDRAC is disabled.
7