CLI Guide

switch–<n>: where n=1–6
-v — VLAN settings has following legal values: no arguments imply remove VLAN tag, not compatible with
server–nx (for example "server–4b") notation <vlan_id>=between 1 and 4000, 4021 and 4094, inclusive
<vlan_priority>=between 0 and 7, inclusive.
-p — Disables IPv4(default) or IPv6 protocol.
-k — Option has following legal values: no arguments imply autonegotiate <speed>=10, 100 <duplex> =half,
full.
NOTE:
-o, -k, -p: These options can be specified for chassis only
-6: Sets static IPv6 addresses (with -soption). Enables autoconfig for IPv6 (with-d option)
disables IPv6 (with-p option) can be specified for chassis or servers.
-v: When performing on a switch, release and renew any DHCP lease on that port for changes to
take effect.
Example
Configuration of Speed= 100 Mbps and duplex= full duplex.
racadm setniccfg -k 100 full
Configuration of Speed and Duplex to Autonegotiate.
racadm setniccfg -k
Configuration of VLAN id and priority of a slot or all blades in a sleeve.
racadm setniccfg -i 5 -v 1000 7
Configuration of CMC to a static IPv6 address.
racadm setniccfg -m chassis -s -6 2001:DB8::2 64 2001:DB8::1
Configuration of server to use stateless autoconfiguration address.
racadm setniccfg -m server-1 -d -6
Configuration of VLAN id and priority for a switch.
racadm setniccfg -m switch-1 -v 1000 7
Removal of VLAN configuration from a switch.
racadm setniccfg -m switch-1 -v
Configuration of redundant mode
racadm setniccfg -r 1
setractime
Table 112. Details of setractime attribute
Description Sets the date and time on the CMC.
To run this subcommand, you must have the Administrator privilege.
Synopsis
racadm setractime -d <YYYYMMDDhhmmss.mmmmmmsoff>
racadm setractime -l <YYYYMMDDhhmmss>
racadm setractime -z ?|<timezone>|<timezone-prefix>*
RACADM Subcommand Details 81