CLI Guide

If the fabric type is determined to be InfiniBand, the operation is canceled and the command returns an error. If the
FlexAddress feature is not activated, the command returns an error.
NOTE: The server must be turned off to change the slot state. All servers must be turned off to
change the fabric state. The MAC/WWN addresses must be managed locally (not by an external
console) to run this command.
Synopsis
racadm setflexaddr -i <slotNum> 0|1
racadm setflexaddr -f <fabricName> 0|1
Input
-i <slotNum> — Enables or disables FlexAddress for the specified slot.
-f <fabricName> — Enables or disables FlexAddress for the specified fabric.
<slotNum>= 1–16
<fabricName>= A, B, C, iDRAC
0 : Disable
1 : Enable
Example
Disable flexaddress for slot 2.
racadm setflexaddr -i 2 0
Enable flexaddress for fabric A.
racadm setflexaddr -f A 1
Disable flexaddress for fabric B.
racadm setflexaddr -f b 0
Disable flexaddress for fabric iDRAC.
racadm setflexaddr -f idrac 0
setled
Table 110. Details of setled attribute
Description Sets the state (blinking or not blinking) of the LED on the specified module.
To blink or unblink the chassis, I/O modules or the CMC, you must have the Debug Administrator privilege. To
enable the servers to blink or unblink, you must have the Server Administrator or the Debug Administrator privilege.
Synopsis
racadm setled -m <module> -l <ledState>
Input
-m <module> — Specifies the module whose LED you want to configure.
<module> can be one of the following:
server–<n>, where n=1–16
server–<nx>, where n=1–8; x = a, b, c, d (lower case)
switch–<n>, where n=1–6
cmc-active
chassis
-l <ledState> — Specifies the LED state. The values are:
0 — No Blinking
1 — Blinking
RACADM Subcommand Details 79