CLI Guide

Table 66. Example
System Input Power = 1574 W
Peak System Power = 1916 W
Peak System Power Timestamp = 09:29:20 11/26/2014
Minimum System Power = 374 W
Minimum System Power Timestamp = 09:20:51 11/26/2014
Overall Power Health = OK
Redundancy = No
System Input Power Cap = 16685 W
Redundancy Policy = None
Dynamic PSU Engagement Enabled = No
System Input Max Power Capacity = 16685 W
Input Redundancy Reserve = 0 W
Input Power Allocated to Servers = 1826 W
Input Power Allocated to Chassis
Infrastructure
= 1212 W
Total Input Power Available for
Allocation
= 13648 W
Standby Input Power Capacity = 0 W
Server Based Power Management Mode = No
Max Power Conservation Mode = No
Server Performance Over Power Redundancy = No
Power Available for Server Power-on = 13648 W
Extended Power Performance (EPP) Status = Disabled
Available Power in EPP Pool = 0 W (0 BTU/h)
Used Power in EPP Pool = 0 W (0 BTU/h)
EPP Percent - Available = 0.0
Table 67. Chassis Power Supply Status Table
<Name> <Model> <Power State> <Input
Current>
<Input
Volts>
<Output Rated
Power>
PS1 08V4DK Online 1.0 A 240.0 V 3000 W
PS2 08V4DK Online 1.9 A 239.2 V 3000 W
PS3 08V4DK Online 1.1 A 239.5 V 3000 W
PS4 08V4DK Online 1.1 A 239.5 V 3000 W
PS5 08V4DK Online 1.0 A 239.8 V 3000 W
PS6 08V4DK Online 1.9 A 239.8 V 3000 W
Table 68. Server Module Power Allocation Table
<Slot#> <Server Name> <PowerState
>
<Allocation> <Priori
ty>
<Blade Type>
1 SLOT-01 ON 114 W 1 PowerEdge M630
RACADM Subcommand Details 57