CLI Guide
Table 36. For Slot 9
<Fabric> <Type> <Server-Assigned> <Chassis-Assigned>
slot9-idrac Controller 18:A9:9B:FD:C1:C9 F8:BC:12:E5:FE:98(ac
tive)
slot9-A1 10 GbE KR 00:90:FA:51:2E:22
F8:BC:12:E5:FE:99(ac
tive)
10 GbE KR/3 00:90:FA:51:2E:23
F8:BC:12:E5:FE:9B(ac
tive)
FCoE-WWN 10:00:00:90:FA:51:2E
:23
20:01:F8:BC:12:E5:FE
:9B(active)
slot9-A2 10 GbE KR 00:90:FA:51:2E:2A F8:BC:12:E5:FE:9A(ac
tive)
slot9-B1 Gigabit Ethernet A0:36:9F:12:3D:38 F8:BC:12:E5:FE:9D(ac
tive)
NOTE:
10 GbE KR/3— The value 3 indicates that the fabric is iSCSI/FCoE-FIP.
getfanreqinfo
Table 37. Details of getfanreqinfo attribute
Description Displays fan speed request for servers and switches in percent (%).
To run this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getfanreqinfo
Input N/A
Output None
Table 38. Example
<Slot#> <Server Name> <Blade Type> <Power State> <Presence
>
<Fan
Request
%>
1 SLOT-01 N/A N/A Not
Present
N/A
2 WIN-JGKC47ACGKG PowerEdge M630 ON Present 38
3 WIN-N24BRAT3L1J PowerEdge M630 ON Present 38
42 RACADM Subcommand Details