CLI Guide

Displays the current Enhanced Cooling Mode property
configuration.
racadm getconfig –g cfgThermal
getdcinfo
Table 29. Details of getdcinfo attribute
Description Displays general I/O module and daughter card configuration information. Only the CMC controls daughter cards.
To run this subcommand, you must have the CMC Login User privilege.
NOTE: Fabric verification for server DCs is performed only when the chassis is turned on. When the
chassis is on standby power, iDRACs on the server modules remain turned off and thus are unable to
report the server's DC fabric type. The DC fabric type may not be reported in the CMC user
interface until iDRAC on the server is turned on.
Synopsis
racadm getdcinfo
racadm getdcinfo [-n]
Input -n — Displays the model names for the daughter cards in servers.
Table 30. Example 1
<IO#> <Type> <State> <Role>
switch-1 Gigabit Ethernet OK Master
switch-2 None N/A N/A
switch-3 Gigabit Ethernet OK Master
switch-4 None N/A N/A
switch-5 Gigabit Ethernet OK Member
switch-6 None N/A N/A
Table 31. Example 2
<Server#> <Presence> <DC1 Type> <DC1 State> <DC2 Type> <DC2 State>
server-1 Present None N/A None N/A
server-2 Not Present None N/A None N/A
server-3 Not Present None N/A None N/A
38 RACADM Subcommand Details