CLI Guide
Output
This subcommand generates error output for any of the following reasons:
• Invalid syntax, group name, object name, index or other invalid database members.
• If the RACADM command-line interface is unsuccessful.
Examples
• To configure a single property of a group:
racadm config -g cfgSerial -o cfgSerialBaudRate
• Modify a user password:
racadm config -g cfgUserAdmin -o cfgUserAdminPassword -i 3 newpassword
• Configure a RAC from a configuration file:
racadm config -f config.txt
• Configure a RAC from a configuration file and continue if a group fails to get configured:
racadm set -f config.txt --continue
connect
Table 14. Details of connect attribute
Description Connects to the switch or blade server serial console.
NOTE: This subcommand is only supported on the firmware interface(s).
Synopsis
• racadm connect [-b] —m <module>
Input
-b — Connects to the switch or console using the binary mode. -b is an optional; a server or a switch must be
present.
NOTE: If you use the -b option, reset the CMC to end the connect operation.
-m <module> — Must be one of the following values:
• server –<n> — where n=1–16
• server –<nx> — where n=1–8; x = a, b, c, d (lower case)
• switch –<n> — where n = 1 to 6 or <a1 | a2 | b1 | b2 | c1 | c2>
Example
• Connect to I/O Module 1 serial console:
racadm connect -m switch-1
• Connect to server 1 serial console:
racadm connect -m server-1
deploy
Table 15. Details of deploy attribute
Description Deploys blade server or IOM by specifying the required properties.
To use this subcommand, you must have the Server Administrator privilege.
NOTE: Use setniccfg to configure static IP address, subnet mask, and gateway, and DHCP, speed
and duplex properties.
22 RACADM Subcommand Details