CLI Guide

Firmware RACADM:
racadm config -g cfgserverinfo -i <server_slot_number> -o
cfgServerDNSIMCName <Valid_iDRAC_Name>
Remote RACADM:
racadm -r <cmc_ip> -u <cmc_username> -p <cmc_password> config -g
cfgserverinfo -i <server_slot_number> -o cfgServerDNSIMCName
<Valid_iDRAC_Name>
Proxy:
racadm -r <iDRAC_ip> -u <iDRAC_username> -p <iDRAC_password> config -g
cfgserverinfo -i <server_slot_number> -o cfgServerDNSIMCName
<Valid_iDRAC_Name> --proxy
To get the iDRAC DNS name in:
Firmware RACADM:
racadm getconfig -g cfgserverinfo -i <server_slot_number> -o
cfgServerDNSIMCName
Remote RACADM:
racadm -r <cmc_ip> -u <cmc_username> -p <cmc_password> getconfig -g
cfgserverinfo -i <server_slot_number> -o cfgServerDNSIMCName
Proxy:
racadm -r <iDRAC_ip> -u <iDRAC_username> -p <iDRAC_password> getconfig -g
cfgserverinfo -i <server_slot_number> -o cfgServerDNSIMCName --proxy
cfgServerRootPassword (Write Only)
Table 240. Details of cfgServerRootPassword attribute
Description Displays the password for IMC as a series of asterisks (*). It cannot be seen or displayed after this property is
written.
Legal Values
None
Default
None
cfgServerFirstBootDevice (Read or Write)
Table 241. Details of cfgServerFirstBootDevice attribute
Description Sets or displays the first boot device.
NOTE: First attach, to configure vFlash as First Boot Device. When a detached or non-existent
vFlash partition or a nonstandard boot device is configured as first boot device, the following error
message is displayed:
Invalid object value
Legal Values
No-Override
PXE
HDD
CD-DVD
BIOS
126 CMC Property Database Group and Object Descriptions