Release Notes

Known Issues
Flex disabled address after racresetcfg of CMC
Description XWKGY_Intel10G card shows Flex disabled address after racresetcfg of CMC in the Network Device page
and OS.
Resolution Virtual reseat or physical reseat of the server.
Versions/Systems
aected
All CMC versions including CMC 6.10 and the PowerEdge servers with iDRAC7 or earlier.
Error occurs while importing CMC conguration le
Description An error occurs while importing CMC conguration le using local or remote RACADM.
Resolution This issue occurs when IPv6 is enabled or disabled from the conguration le. Enable or disable IPv6 using the
command, racadm config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0.
Versions/Systems
aected
CMC version 5.11 or later
Server components update page gets corrupt
Description
When CMC rmware is downgraded to 4.50 from 5.00 or later while network share is congured, the Server
Components Update page gets corrupt.
Resolution Clear the network conguration before downgrading to 4.50.
Versions/Systems
aected
CMC version 4.50 or earlier
Unable to view chassis logs from remote RACADM
Description
Unable to view chassis logs from remote RACADM
Resolution None
Use rmware RACADM instead, to view the chassis logs.
Versions/Systems
aected
All CMC versions including 6.20 using OM 911 and later.
Tracking number 109003
7
14 Known Issues