CLI Guide
Clear SEL log on server 1
cmcchangeover
Table 12. Details of cmcchangeover attribute
Description Changes the state of the CMC from active to standby, or from standby to active, in a redundant CMC conguration.
This subcommand is useful for remote debugging or testing purposes
To use this subcommand, you must have the Administrator privilege.
NOTE: This command is applicable only in redundant CMC environments. For more information, see the
"Understanding the Redundant CMC Environment" section of the
Dell Chassis System User Guide.
Synopsis
racadm cmcchangeover
Input
N/A
Output
CMC failover initiated successfully.
Example
racadm cmcchangeover
cong
Table 13. Details of
cong attribute
Description
Allows you to set iDRAC conguration parameters individually or to batch them as part of a conguration le and
then modify iDRAC conguration properties. If the data is dierent, the iDRAC object is written with a new value.
NOTE: This subcommand will be deprecated in the later versions. For information about congurations,
see the set subcommand.
Synopsis
• racadm config -g <group> -o <object> <value>
• racadm config -g <group> -o <object> -i <index> <value>
• racadm config -f <filename> -o [-c] [-p] [-continue]
NOTE:
• The conguration le retrieved using remote RACADM is not interoperable. For the cong racadm -r
192.168.0 -u root -p xxx config -f c:\config.txt command, use the conguration le
retrieved from the same interface. For example, for the cong
racadm -r 192.168.0 -u root -p
xxx config -f c:\config.txt , use the le generated from getcong command racadm -r
192.168.0 -u root -p xxx getconfig -f c:\config.txt.
• -f is only applicable for remote RACADM.
racadm config -g <group> -o <object> <value> [-m <module>]
Input
• -f — The -f <filename> option causes cong to read the contents of the le specied by <filename>
and congure iDRAC. The le must contain data in the format specied in the section Parsing Rules in the iDRAC
User’s Guide available at www.dell.com/idracmanuals.
NOTE: The -f option is not supported for the Serial or Telnet or SSH console.
NOTE: When the –f option is specied and conguration of an attribute fails, then conguration of
other attributes in that group is skipped.
22 RACADM Subcommand Details