CLI Guide
cfgChassisRedundancyPolicy (Read or Write)
Table 302. Details of cfgChassisRedundancyPolicy attribute
Description
Sets the redundancy policy of the chassis.
Legal Values
• 0 — No redundancy
• 1 — Grid redundancy
• 2 — Power supply redundancy
Default
0 — No redundancy
cfgChassisDynamicPSUEngagementEnable (Read or Write)
Table 303. Details of cfgChassisDynamicPSUEngagementEnable attribute
Description
Enables or disables dynamic engagement.
Legal Values
• 0 — Disabled
• 1 — Enabled
Default 0
cfgChassisAllow110VACOperation (Read or Write)
Table 304. Details of cfgChassisAllow110VACOperation attribute
Description Enables or disables normal chassis power allocations when any PSU is connected to 110V AC service. If disabled and
110V power supplies are detected, all subsequent server power allocation requests are denied. In this mode more
servers cannot be powered on, regardless of server priority.
Legal Values
• 0 — Disabled
• 1 — Enabled
Default
0
cfgChassisAllow110VACOperationTimestamp (Read Only)
Table 305. Details of cfgChassisAllow110VACOperationTimestamp attribute
Description The timestamp recorded when Allow110V setting from power management is enabled.
Legal Values
CMC Property Database Group and Object Descriptions 149