Users Guide
NOTE: Only X509, Base-64 encoded certicates are accepted by CMC. Certicates using other encoding schemes such as
DER, are not accepted. Uploading a new certicate replaces the default certicate you received with your CMC.
CMC resets and becomes temporarily unavailable after the certicate has been uploaded successfully. To avoid disconnecting other
users during a reset, notify authorized users who might log into CMC and check for active sessions in the Sessions page under the
Network tab.
Uploading Webserver Key and Certicate Using RACADM
To upload SSL key from the client to iDRAC, type the following command:
racadm sslkeyupload -t <type> -f <filename>
For more information, see the Chassis Management Controller for Dell PowerEdge M1000e RACADM Command Line Reference Guide
available at dell.com/support/manuals.
Viewing Server Certicate
You can view the SSL server certicate that is currently being used in CMC.
Viewing Server Certicate Using Web Interface
In the CMC Web interface, go to Chassis Overview > Network > SSL. Select View Server Certicate and click Next. The View Server
Certicate page displays the SSL server certicate currently in use. For more information, see CMC Online Help.
NOTE
: The server certicate displays the common name as the rack name appended with the domain name, if available. Else,
only the rack name is displayed.
Viewing Server Certicate Using RACADM
To view the SSL server certicate, use the sslcertview command. For more information, see the Chassis Management Controller for
Dell PowerEdge M1000e RACADM Command Line Reference Guide available at dell.com/support/manuals.
Chassis Conguration Proles
The Chassis Conguration Proles feature enables you to congure the chassis with the chassis conguration proles stored in the
network share or local management station, and also restore conguration of the chassis.
To access the Chassis Conguration Proles page in the CMC web interface, in the system tree, go to Chassis Overview and click Setup
> Proles. The Chassis Conguration Proles page is displayed.
You can perform the following tasks by using the Chassis Conguration Proles feature:
• Congure a chassis using chassis conguration proles in local management station for initial conguration.
• Save the current chassis conguration settings to an XML le on the network share or local management station.
• Restore the chassis conguration.
• Import chassis proles (XML les) to the network share from a local management station.
• Export chassis proles (XML les) from the network share to a local management station.
• Apply, edit, delete, or export a copy of the proles stored on the network share.
Conguring
CMC 97