Users Guide

Select only those setting categories that you want identically congured, across all members of the chassis group. For example, select
Logging and Alerting Properties category, to enable all chassis in the group to share the logging and alerting conguration settings of
the lead chassis.
6 Click Save.
If On-Change Propagation is selected, the member chassis take on the properties of the leader. If Manual Propagation is selected,
click
Propagate whenever you want to propagate the chosen settings to member chassis. For more information on Propagation of
leader chassis properties to member chassis, see the CMC Online Help.
Server Inventory for Multi Chassis Management Group
The Chassis Group Health page displays all the member chassis and allows you to save the server inventory report to a le, using standard
browser download capability. The report contains data for:
All servers currently in all the group chassis (including the leader.)
Empty slots and extension slots (including full height and double width servers.)
Saving Server Inventory Report
To save the server inventory report using CMC Web interface:
1 In the system tree, select the Group.
The Chassis Group Health page is displayed.
2 Click Save Inventory Report.
The File Download dialog box is displayed prompting you to open or save the le.
3 Click Save and specify the path and lename for the server inventory report.
NOTE
: The Chassis Group leader, member chassis, and the servers in the associated chassis, must be On to get the most
accurate server inventory report.
Exported Data
The server inventory report contains data that was most recently returned by each Chassis Group member during the Chassis Group
leader’s normal polling (once every 30s.)
To get the most accurate server inventory report:
The Chassis Group leader chassis and all Chassis Group member chassis must be in Chassis Power State On.
All servers in the associated chassis must be powered on.
The inventory data for the associated chassis and servers may be missing in inventory report, if a subset of the Chassis Group member
chassis is:
In Chassis Power State O
Powered o
NOTE
: If a server is inserted while the chassis is powered o, the model number is not displayed anywhere in the Web interface
until the chassis is powered back.
The following table lists the specic data elds and specic requirements for elds to be reported for each server:
Data Field
Example
Chassis Name Data Center Chassis Leader
Conguring CMC 91