Users Guide

Severity Message Cause
Critical The storage battery failed. CMOS battery is not present or has no voltage.
Critical The CPU <number> <voltage sensor name > voltage
is outside of the allowable range.
Critical The system board<voltage sensor name > voltage is
outside of the allowable range.
Critical The mezzanine card <number> <voltage sensor name
> voltage is outside of the allowable range.
Critical The storage <voltage sensor name > voltage is
outside of the allowable range.
Critical CPU <number> has an internal error (IERR). CPU failure.
Critical CPU <number> has a thermal trip (over-temperature)
event.
CPU overheated.
Critica CPU <number> conguration is unsupported. Incorrect processor type or in wrong location.
Critical CPU <number> is absent. Required CPU is missing or not present.
Critical Mezz B<slot number> Status: Add-in Card sensor for
Mezz B<slot number>, install error was asserted.
Incorrect Mezzanine card installed for IO fabric.
Critical Mezz C<slot number> Status: Add-in Card sensor for
Mezz C<slot number>, install error was asserted.
Incorrect Mezzanine card installed for IO fabric.
Critical Drive <number> is removed. Storage Drive was removed.
Critical Fault detected on Drive <number>. Storage Drive failed.
Critical The system board fail-safe voltage is outside of the
allowable range.
This event is generated when the system board voltages are
not at normal levels.
Critical The watchdog timer expired. The iDRAC watchdog timer expires and no action is set.
Critical The watchdog timer reset the system. The iDRAC watchdog detected that the system has
crashed (timer expired because no response was received
from Host) and the action is set to reboot.
Critical The watchdog timer powered o the system. The iDRAC watchdog detected that the system has
crashed (timer expired because no response was received
from Host) and the action is set to power o.
Critical The watchdog timer power cycled the system. The iDRAC watchdog detected that the system has
crashed (timer expired because no response was received
from Host) and the action is set to power cycle.
Critical Log is full. The SEL device detects that only one entry can be added
to the SEL before it is full.
Warning Persistent correctable memory errors detected on a
memory device at location <location>.
Warning Persistent correctable memory error rate has
increased for a memory device at location <location>.
Correctable ECC errors reach a critical rate.
Critical Multi-bit memory errors detected on a memory device
at location <location>.
An uncorrectable ECC error was detected.
Using LCD Panel Interface 261