Users Guide
where n is 1-1440 minutes.
• To determine if the power remote logging feature is enabled, type the following command:
racadm getconfig -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingEnabled
• To determine the power remote logging interval, type the following command:
racadm getconfig -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingInterval
The power remote logging feature is dependent on remote syslog hosts having been previously congured. Logging to one or more
remote syslog hosts must be enabled, otherwise power consumption is logged. This can be done either through the Web interface
or the RACADM CLI. For more information, see the remote syslog conguration instructions in the Chassis Management
Controller for Dell PowerEdge M1000e RACADM Command Line Reference Guide at dell.com/support/manuals.
• To enable remote power management using the Dell OpenManage Power Center, type:
racadm config -g cfgChassisPower -o cfgChassisServerBasedPowerMgmtMode 1
• To restore CMC power management, type:
racadm config -g cfgChassisPower -o cfgChassisServerBasedPowerMgmtMode 0
For information about RACADM commands for chassis power, see the cong, getcong, getpbinfo, and cfgChassisPower sections in
the Chassis Management Controller for Dell PowerEdge M1000e RACADM Command Line Reference Guide.
Executing Power Control Operations
You can execute the following power control operation for the chassis, servers, and IOMs.
NOTE: Power control operations aect the entire chassis.
Related links
Executing Power Control Operations on the Chassis
Executing Power Control Operations on a Server
Executing Power Control Operations on an IOM
Executing Power Control Operations on the Chassis
CMC enables you to remotely perform several power management actions, such as an orderly shutdown, on the entire chassis (chassis,
servers, IOMs, iKVM, and PSUs).
NOTE
: To perform power management actions, you must have Chassis Conguration Administrator privilege.
Executing Power Control Operations on the Chassis Using Web Interface
To execute power control operations on the chassis using the CMC Web interface:
1 In the system tree, go to Chassis Overview and click Power > Control.
The Chassis Power Control page is displayed.
2 Select one of the following power control operations:
• Power On System
• Power O System
• Power Cycle System (cold boot)
• Reset CMC (warm boot)
• Non-Graceful Shutdown
For information about each option, see the CMC Online Help.
3 Click Apply.
A dialog box appears requesting conrmation.
Managing and Monitoring Power
235