To display the iSCSI MAC addresses for all servers, use the following RACADM command:
racadm getmacaddress -t iscsi
To display the iSCSI MAC for a specic server, use the following RACADM command:
racadm getmacaddress [-m <module> [-x]] [-t iscsi]
To display the user-dened MAC and WWN address, use the following RACADM command:
racadm getmacaddress -c io-identity
racadm getmacaddress -c io-identity -m server -2
To display the console assigned MAC/WWN of all LOMs or mezzanine cards, use the following RACADM command:
racadm getmacaddress -c all
To display the chassis assigned WWN/MAC address, use the following RACADM command:
racadm getmacaddress -c flexaddress
To display the MAC/WWN addresses for all LOMs or mezzanine cards, use the following RACADM command:
racadm getmacaddress -c factory
To display the Ethernet and iSCSI MAC/WWN addresses for all iDRAC/LOMs/mezzanine cards, use the following RACADM command:
racadm getmacaddress -a
For more information on the getexaddr and getmacaddress subcommand, see the Chassis Management Controller for PowerEdge
M1000e RACADM Command Line Reference Guide.
Viewing World Wide Name or Media Access Control
IDs
The WWN/MAC Summary page allows you to view the World Wide Name (WWN) conguration and Media Access Control (MAC)
address of a slot in the chassis.
Fabric Conguration
The Fabric Conguration section displays the type of Input/Output fabric that is installed for Fabric A, Fabric B, and Fabric C. A green
check mark indicates that the fabric is enabled for FlexAddress. The FlexAddress feature is used to deploy chassis assigned and slot
persistent WWN/MAC addresses to various fabrics and slots within the chassis. This feature is enabled on a per fabric and per slot basis.
NOTE
: For more information on the FlexAddress feature, see About Flexaddress.
WWN or MAC Addresses
The WWN/MAC Address section displays the WWN/MAC information that is assigned to all servers, even if those server slots are
currently empty.
• Location displays the location of the slot occupied by the Input/Output modules. The six slots are identied by a combination of the
group name (A, B, or C) and slot number (1 or 2): slot names A1, A2, B1, B2, C1, or C2. iDRAC is the server's integrated management
controller.
• Fabric displays the type of the I/O fabric.
• Server-Assigned displays the server-assigned WWN/MAC addresses embedded in the controller's hardware.
• Chassis-Assigned displays the chassis-assigned WWN/MAC addresses used for the particular slot.
Using FlexAddress and FlexAdress Plus Cards