To display the iSCSI MAC addresses for all servers, use the following RACADM command:
racadm getmacaddress -t iscsi
To display the iSCSI MAC for a specic server, use the following RACADM command:
racadm getmacaddress [-m <module> [-x]] [-t iscsi]
To display the user-dened MAC and WWN address, use the following RACADM command:
racadm getmacaddress -c io-identity
racadm getmacaddress -c io-identity -m server -2
To display the console assigned MAC/WWN of all LOMs or mezzanine cards, use the following RACADM command:
racadm getmacaddress -c all
To display the chassis assigned WWN/MAC address, use the following RACADM command:
racadm getmacaddress -c flexaddress
To display the MAC/WWN addresses for all LOMs or mezzanine cards, use the following RACADM command:
racadm getmacaddress -c factory
To display the Ethernet and iSCSI MAC/WWN addresses for all iDRAC/LOMs/mezzanine cards, use the following RACADM command:
racadm getmacaddress -a
For more information on the getexaddr and getmacaddress subcommand, see the Chassis Management Controller for PowerEdge
M1000e RACADM Command Line Reference Guide.
Viewing World Wide Name or Media Access Control
IDs
The WWN/MAC Summary page allows you to view the World Wide Name (WWN) conguration and Media Access Control (MAC)
address of a slot in the chassis.
Fabric Conguration
The Fabric Conguration section displays the type of Input/Output fabric that is installed for Fabric A, Fabric B, and Fabric C. A green
check mark indicates that the fabric is enabled for FlexAddress. The FlexAddress feature is used to deploy chassis assigned and slot
persistent WWN/MAC addresses to various fabrics and slots within the chassis. This feature is enabled on a per fabric and per slot basis.
NOTE
: For more information on the FlexAddress feature, see About Flexaddress.
WWN or MAC Addresses
The WWN/MAC Address section displays the WWN/MAC information that is assigned to all servers, even if those server slots are
currently empty.
Location displays the location of the slot occupied by the Input/Output modules. The six slots are identied by a combination of the
group name (A, B, or C) and slot number (1 or 2): slot names A1, A2, B1, B2, C1, or C2. iDRAC is the server's integrated management
controller.
Fabric displays the type of the I/O fabric.
Server-Assigned displays the server-assigned WWN/MAC addresses embedded in the controller's hardware.
Chassis-Assigned displays the chassis-assigned WWN/MAC addresses used for the particular slot.