Users Guide
To copy the QuickDeploy settings into the iDRAC Network Settings section, click Auto-Populate Using QuickDeploy Settings. The
QuickDeploy network congurations settings are copied into the corresponding elds in the iDRAC Network Conguration Settings
table.
NOTE: Changes made to QuickDeploy elds are immediate, but changes made to one or more iDRAC server network
conguration settings may require a couple of minutes to propagate from CMC to iDRAC. Clicking Refresh too soon may
display only partially correct data for one or more iDRAC servers.
QuickDeploy IP Address Assignments For Servers
The gure here shows the QuickDeploy IP addresses assignment to the servers when there are eight full height servers in a M1000e
chassis:
The following gure shows the QuickDeploy IP addresses assignment to the servers when there are 16 half height severs in a M1000e
chassis:
The following gure shows the QuickDeploy IP addresses assignment to the servers when there are 32 quarter height severs in a M1000e
chassis:
Conguring Reserved QuickDeploy IP Addresses Using RACADM
To modify the number of static IP addresses allocated for servers on the chassis using RACADM, use the following command:
racadm deploy –q -n <num>
where <num> is the number of IP addresses, 8. 16, or 32.
To view current settings for the number of reserved IP addresses and the Use CMC DNS Settings for servers on the chassis using
RACADM, use the following command:
racadm deploy –q
To modify the Use the CMC DNS Settings option to enable quick deploy for servers on the chassis using RACADM, use the following
command:
racadm deploy -q -e <enable/disable>
For more information, see the Chassis Management Controller for Dell PowerEdge M1000e RACADM Command Line Reference Guide
available at dell.com/support/manuals.
112