CLI Guide

# idRacDescriptionInfo=This system component provides a complete
set of remote management functions for blade servers
# idRacVersionInfo=P21
# idRacBuildInfo=200708301525
# idRacName=CMC-1
racadm getconfig -g idRacInfo
# idRacType=16
# idRacProductInfo=Integrated Dell Remote Access Controller
# idRacDescriptionInfo=This system component provides a complete set of remote management
functions for Dell PowerEdge Servers
# idRacVersionInfo=1.06.06
# idRacBuildInfo=15
# idRacName=idrac-GSRS3V1
cfgLanNetworking
This group contains parameters to congure CMC NIC for IPv4.
One instance of the group is allowed. Some objects in this group may require CMC NIC to be reset, which may cause a brief loss in
connectivity. Objects that change CMC NIC IP address settings close all active user sessions and require users to reconnect using the
updated IP address settings.
Use this object with the cong or getcong subcommands.
To use this object property, you must have the Chassis Conguration Administrator privilege.
NOTE
: You can congure a setting that does not have a hash sign (#) prexed in the output. To modify a congurable object, use
the —o option.
The following sections provide information about the objects in the cfgLanNetworking group.
cfgNicIPv4Enable (Read or Write)
Table 135. Details of cfgNicIPv4Enable attribute
Description
Enables or disables IPv4 stack.
Legal Values
1 (TRUE)
0 (FALSE)
Default
0
cfgNicVLanEnable (Read or Write)
Table 136. Details of attribute - cfgNicVLanEnable
Description
Enables or disables the VLAN capabilities.
All chassis management trac, including the CMC and all iDRACs, resides on this external VLAN when enabled. No
iDRAC conguration change is required to use this external management network VLAN.
Legal Values
1 (TRUE)
CMC Property Database Group and Object Descriptions 95