CLI Guide

Example
Set member name, member IP, member netmask, member gateway with new group name, group IP, group
password, admin password selecting fabric A on server-1.
racadm setarraycfg -m server-1 -n cmc-col 192.168.1.233 255.255.255.0
192.168.1.0 -e 0 -g cmc-array-grp 192.168.1.10 <password> -f A
Set member name, member IP, member netmask, member gateway with existing group name, group IP, group
password selecting fabric B on server-1.
racadm setarraycfg -m server-1 -n cmc-col 192.168.1.233 255.255.255.0
192.168.1.0 -e 1 -g cmc-array-grp 192.168.1.10 <password> -f B
Select dierent fabric type.
racadm setarraycfg -m server-3 -f A
setassettag
Table 108. Details of setassettag attribute
Description Sets the N-byte ASCII asset tag for the chassis.
To use this subcommand, you must have the Administrator privilege.
NOTE: The special characters “ (double quotation mark), ‘ (backward quotation mark), & (ampersand),
and \ (backward slash) are not supported for this subcommand.
Synopsis
racadm setassettag -m module <assettag>
Input -m <module>Species the module whose asset tag you want to set.
Legal value: chassis
You can obtain the same output if you do not include this option, as there is only one legal value.
<assettag> is a maximum of 64 non-extended ASCII characters.
Example
racadm setassettag -m chassis 783839–33
racadm setassettag 783839–33
The asset tag was changed successfully.
setchassisname
Table 109. Details of setchassisname attribute
Description Sets the name of the chassis in the LCD.
To run this subcommand, you must have the Administrator privilege.
NOTE: The special characters “ (double quotation mark), ‘ (backward quotation mark), & (ampersand), >
(greater than), < (less than), and \ (backward slash) are not supported for this subcommand.
Synopsis
racadm setchassisname <name>
NOTE: Chassis name is a maximum of 64 nonextended ASCII characters.
Example
racadm setchassisname dellchassis-1
The chassis name was set successfully.
RACADM Subcommand Details 77