CLI Guide
Jul 31 14:15:49 CMC-4C2WXF1 Extended Power Performance is Enabled
Jul 31 14:15:49 CMC-4C2WXF1 Extended Power Performance is Disabled
• When Enhanced Logging mode is enabled, the output of getraclog is displayed similar to chassislog
output.
Using racadm config -g cfgRacTuning -o cfgRacTuneEnhancedLog 1 command, Enhanced
Logging feature is enabled.
SeqNumber = 38
Message ID = USR8501
Category = Audit
AgentID = CMC
Severity = Information
Timestamp = 2014-10-18 15:48:10
Message Arg 1 = 14503
Message Arg 2 = 48186
Message = Successfully closed Session process: pid=14503 sid=4818
getractime
Table 71. Details of getractime attribute
Description Displays the current CMC time.
Synopsis
• racadm getractime [-d]
• racadm getractime [-d] [-z]
• racadm getractime [-n]
Input
• -d — Displays the time in the format, YYYYMMDDhhmmss.
• -z — Displays timezone.
• -n — Displays NTP peer information.
NOTE: If the options are not provided, then the getractime subcommand displays the time in a common
readable format.
Output The current CMC time is displayed.
Example
• racadm getractime
Mon May 13 17:17:12 2013
• racadm getractime -d
20141126114423
getredundancymode
Table 72. Details of getredundancymode attribute
Description Displays the redundancy status (Redundant or Non-Redundant) of the CMC.
To run this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getredundancymode
Input N/A
Example
racadm getredundancymode
58 RACADM Subcommand Details