CLI Guide
Switch-6 N/A None Not Present N/A
[Enhanced Cooling Mode]
Enhanced Cooling Mode(ECM) Status = Disabled
getioinfo
Table 39. Details of getioinfo attribute
Description Displays general information about the I/O modules on the chassis.
To run this subcommand, you must have the CMC Login User privilege.
NOTE: The fabric type may be any supported I/O fabric type, such as Ethernet, Fibre Channel, and
InniBand.
Synopsis
• racadm getioinfo [-m <module>] [-s]
• racadm getioinfo -o
• racadm getioinfo -m switch-<n> -o
Input
• -m <module> — Species the module or device.<module> must be switch — <n>, where n = 1–6
• -s — Displays stack information.
• -o — Displays IOA Flex module information. The possible values for the ex module type are:
– 0 — 4x10G Base-T FlexIO Module
– 1 — 4x10G SFP+ FlexIO Module
– 2 — 2x40G QSFP+ FlexIO Module
– 3 — 4xFC FlexIO Module
– 4 — No flex module installed
– >4 — Invalid
Example
•
Table 40. racadm getioinfo
<IO> <Name> <Type> <Presence> <POST> <Power> <Role> <SecureMode> <Mode>
switch
-1
MXL
10/40GbE
10 GbE KR Present OK ON Master
No
Full
Switch
switch
-2
PowerEdge
M I/O
Aggregato
r
10 GbE KR Present OK ON Standal
one
No
Standalo
ne
switch
-3
Brocade
M6505
Fibre
Channel
16
Present OK ON Master
No
Standalo
ne
switch
-4
Brocade
M6505
Fibre
Channel
16
Present OK ON Master
No
Standalo
ne
switch
-5
PowerEdge
M I/O
10 GbE KR Present OK ON Standal
one
No
Standalo
ne
RACADM Subcommand Details 43